Shrnutí obsahu

Strany 1 - Powerware

Powerware®9150User’s Guide8kVA-12.5kVAwww.powerware.com02/20/2001

Strany 2 - FCC Statement

Safety Warnings6Powerware®9150 User’s Guide www.powerware.comDANGERThisUPScontainsLETHAL VOLTAGES.Allrepairsand serviceshould be performedbyAUTHORIZED

Strany 3 - TABLE OF CONTENTS

Safety Warnings7Powerware®9150 User’s Guide www.powerware.comSikkerhedsanvisningerFAREDenneUPS(ubrudt strømforsyning)indeholderLIVSFARLIG SPÆNDING.Alr

Strany 4 - Table of Contents

Safety Warnings8Powerware®9150 User’s Guide www.powerware.comBelangrijke VeiligheidsinstructiesGEVAARDezeUPSbevat LEVENSGEVAARLIJKEELEKTRISCHE SPANNIN

Strany 5 - INTRODUCTION

Safety Warnings9Powerware®9150 User’s Guide www.powerware.comTärkeitä turvaohjeitaVAARATämä UPS sisältää HENGENVAARALLISIA JÄNNITTEITÄ. Kaikkikorjauks

Strany 6 - Load Requirements

Safety Warnings10Powerware®9150 User’s Guide www.powerware.comConsignes de SécuritéConsignes Importantes De Sécurité - Conserver Ces InstructionsCette

Strany 7 - Battery Times

Safety Warnings11Powerware®9150 User’s Guide www.powerware.comWichtige SicherheitsanweisungenWARNUNGLebensgefahr! DieseUSVenthält TÖDLICHE SPANNUNGEN!

Strany 8 - Introduction

Safety Warnings12Powerware®9150 User’s Guide www.powerware.comImportanti istruzioni di sicurezzaPERICOLOLaTENSIONE contenuta inquestogruppo staticodi

Strany 9 - SAFETY WARNINGS

Safety Warnings13Powerware®9150 User’s Guide www.powerware.comViktig SikkerhetsinformasionFARLIGDenneUPS’en inneholder LIVSFARLIGE SPENNINGER.Allrepar

Strany 10 - Safety Warnings

Safety Warnings14Powerware®9150 User’s Guide www.powerware.comRegulamentos de SegurançaCUIDADOOUPScontémVOLTAGEMMORTAL. Todos osreparose assistênciaté

Strany 11 - Sikkerhedsanvisninger

Safety Warnings15Powerware®9150 User’s Guide www.powerware.comRequisitos de seguridadPELIGROEsteUPS(suministrodealimentaciónpermanente)contieneVOLTAJE

Strany 12

FCC StatementThe Powerware 9150 UPS configurations vary. Some configurations may or may not be classified by the FederalCommunications Commission (FCC

Strany 13 - Tärkeitä turvaohjeita

Safety Warnings16Powerware®9150 User’s Guide www.powerware.comViktig säkerhetsinformationFARADennaUPS-enhetinnehåller LIVSFARLIGSPÄNNING.ENDAST AUKTOR

Strany 14 - Consignes de Sécurité

17Powerware®9150 User’s Guide www.powerware.comCHAPTER 3INSTALLATIONThe following section describes UPS storage requirements, UPS setup,and the instal

Strany 15 - VORSICHT!

Installation18Powerware®9150 User’s Guide www.powerware.comUPS SetupWhen the UPS is in use, allow a minimum of 4 inches (100 mm) forventilation on bot

Strany 16 - ATTENZIONE

Installation19Powerware®9150 User’s Guide www.powerware.comSeismic MountingThe Powerware 9150 has a seismic mounting option. The UPS isshipped withflo

Strany 17 - Viktig Sikkerhetsinformasion

Installation20Powerware®9150 User’s Guide www.powerware.comSelecting an Installation OptionIn addition to the standard Powerware 9150, the UPS has an

Strany 18 - Regulamentos de Segurança

Installation21Powerware®9150 User’s Guide www.powerware.comUse the following procedure to connect utility power and load to theUPS:1. Verify that the

Strany 19 - Requisitos de seguridad

Installation22Powerware®9150 User’s Guide www.powerware.comLeft Panel ScrewsFigure 5. Removing the UPS Panels

Strany 20 - Viktig säkerhetsinformation

Installation23Powerware®9150 User’s Guide www.powerware.com6. Verify that the UPS battery breaker CB1 and optional CB2 are inthe OFF position (see Fig

Strany 21 - INSTALLATION

Installation24Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Hardwired TerminationsWireFunction TerminalPosition*Upstream CircuitBreakerS

Strany 22 - UPS Setup

Installation25Powerware®9150 User’s Guide www.powerware.com9. Reinstall the UPS left side panel. (Do not reinstall the frontpanel at this time.)10. Lo

Strany 23 - Seismic Mounting

Table of ContentsiPowerware®9150 User’s Guide www.powerware.comTABLE OF CONTENTS1 Introduction 1...UP

Strany 24 - UPS Installation

Installation26Powerware®9150 User’s Guide www.powerware.comLeft Panel ScrewsFigure 8. Removing the UPS Panels

Strany 25

Installation27Powerware®9150 User’s Guide www.powerware.com4. Verify that the UPS battery breaker CB1 and optional CB2 are inthe OFF position (see Fig

Strany 26 - Left Panel Screws

Installation28Powerware®9150 User’s Guide www.powerware.comScrews fromUPS panel; 3 oneach sidereused for PDMWireCover forOutput ConduitLandingFigure 1

Strany 27

Installation29Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Hardwired Terminations for Optional PDMWireFunctionTerminal UpstreamSuggeste

Strany 28

Installation30Powerware®9150 User’s Guide www.powerware.com10. Connect the wire cover to the PDMusing the two screwsprovided (see Figure 10).11. Reins

Strany 29

Installation31Powerware®9150 User’s Guide www.powerware.comCB2CB1 SafetyWireFigure 12. EBC Front Panel5. Verify that the circuit breakers CB1 and CB2

Strany 30

Installation32Powerware®9150 User’s Guide www.powerware.comBattery CableCoverPlateBattery ConnectorUPSEBCEBCEBC Cover Plate (foradditional EBCs)Batter

Strany 31

Installation33Powerware®9150 User’s Guide www.powerware.com10. Lower the leveling feet to prevent the EBC from rolling (doesnot apply for seismic moun

Strany 32

Installation34Powerware®9150 User’s Guide www.powerware.comIf the UPS does not start and an LED other than the UPS ONindicator is blinking, the UPS is

Strany 33

Installation35Powerware®9150 User’s Guide www.powerware.comUPS Startup on BatteryNOTE Beforeusingthisfeature, theUPSmusthave beenpowered byutility pow

Strany 34

Table of ContentsiiPowerware®9150 User’s Guide www.powerware.com4 Operation 39...ControlPanelFuncti

Strany 35 - Figure 12. EBC Front Panel

Installation36Powerware®9150 User’s Guide www.powerware.comConfiguring Voltage and FrequencyThe UPS automatically attempts to match the voltage and fr

Strany 36 - Figure 13. Connecting the EBC

Installation37Powerware®9150 User’s Guide www.powerware.comManual Configuration ModeTo change the nominal output voltage and frequency from the frontp

Strany 37 - UPS Startup

Installation38Powerware®9150 User’s Guide www.powerware.com

Strany 38 - Normal Mode Startup

39Powerware®9150 User’s Guide www.powerware.comCHAPTER 4OPERATIONThis chapter contains information on how to use the Powerware 9150,including UPS shut

Strany 39 - UPS Startup on Battery

Operation40Powerware®9150 User’s Guide www.powerware.comFigure 15. LED PanelThe following table shows the LED status and description.LED Status Descri

Strany 40 - Automatic Configuration Mode

Operation41Powerware®9150 User’s Guide www.powerware.comDescriptionStatusLEDOVERTEMP OnorBlinkingOne of the main UPS components is too hot or the fan

Strany 41 - Manual Configuration Mode

Operation42Powerware®9150 User’s Guide www.powerware.comThe Powerware 9150 can operate in Normal, Bypass, or Battery Mode.The UPS automatically switch

Strany 42

Operation43Powerware®9150 User’s Guide www.powerware.comUPS ShutdownTo shut down the UPS:1. Remove the front panel. Lift from the bottom of the panel

Strany 43 - OPERATION

Operation44Powerware®9150 User’s Guide www.powerware.comMaintenanceBypass SwitchONOFFF1BatteryNeutralFuseCB1InternalBatteryCB2(Optional)ExternalBatter

Strany 44 - Figure 15. LED Panel

Operation45Powerware®9150 User’s Guide www.powerware.comWARNINGIfthe inputfrequencyisnot correctand the UPS is notsynchronizedto utilitypower(LINEONin

Strany 45 - Operating Modes

1Powerware®9150 User’s Guide www.powerware.comCHAPTER 1INTRODUCTIONThe Powerware 9150 is a double-conversion, online uninterruptiblepower supply (UPS)

Strany 46 - Battery Mode

Operation46Powerware®9150 User’s Guide www.powerware.comComputer and Alarm ConnectionsAn interface for direct communication with your computer system

Strany 47 - UPS Shutdown

Operation47Powerware®9150 User’s Guide www.powerware.comConnectUPSMounting BracketCommunicationCablesFigure 19. Hardware ConnectionsRS-232 Serial Data

Strany 48

Operation48Powerware®9150 User’s Guide www.powerware.com123478659Male Connector(LanSafe III/FailSafe III or Modem)543287916Female Connector(OnliNet or

Strany 49 - Operation

Operation49Powerware®9150 User’s Guide www.powerware.comIsolated Alarm Relay InterfaceThe isolated alarm relay interface uses a 15-pin, male, 42D-subc

Strany 50 - Hardware Installation

Operation50Powerware®9150 User’s Guide www.powerware.comRemote Emergency Power-off InputREPO is used to shut down the UPS from a distance. This featur

Strany 51 - RS-232 Serial Data Interfaces

51Powerware®9150 User’s Guide www.powerware.comCHAPTER 5SPECIFICATIONSPowerware 9150 Technical SpecificationsRatedPower 8 kVA, 10 kVA, 12.5 kVA at 0.7

Strany 52 - Figure 20. 9-Pin Serial Port

Specifications52Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Model SpecificationsModel12.5kVAInputCurrent 54A 56A 52A 52A 49AOutputVolt

Strany 53

Specifications53Powerware®9150 User’s Guide www.powerware.comModel8 kVAInputCurrent 39A 40A 36A 36A 35AOutputVoltage 100/200V 110/220V 120/240V 120/20

Strany 54 - Efficiency Optimizer Function

Specifications54Powerware®9150 User’s Guide www.powerware.comEnvironmental and Safety SpecificationsAmbientTemperature 0 Cto+40C operating+15C to +25

Strany 55 - SPECIFICATIONS

55Powerware®9150 User’s Guide www.powerware.comCHAPTER 6TROUBLESHOOTINGThe Powerware 9150 is designed for durable, automatic operationandalso alerts y

Strany 56

Introduction2Powerware®9150 User’s Guide www.powerware.comUPS Model and Battery ConfigurationsThere are two important considerations whenselecting the

Strany 57 - Physical Specifications

Troubleshooting56Powerware®9150 User’s Guide www.powerware.comActionPossibleCauseIndicatororAlarmALARMOn or Blinking1 short and 4 long beeps indicate

Strany 58

Troubleshooting57Powerware®9150 User’s Guide www.powerware.comService and SupportIf you have any questions or problems with your UPS, call for service

Strany 59 - TROUBLESHOOTING

Troubleshooting58Powerware®9150 User’s Guide www.powerware.com

Strany 60 - Silencing the Alarm

Powerware 9150 Limited Warranty (US Only)This limited warranty applies only to units installed in the fifty United States of America. PowerwareCorpora

Strany 61 - Upgrading

60Powerware®9150 User’s Guide www.powerware.com60

Strany 62 - Troubleshooting

Introduction3Powerware®9150 User’s Guide www.powerware.comIf the total load requirements of the equipment exceeds the capacity ofthe UPS, you must eit

Strany 63

Introduction4Powerware®9150 User’s Guide www.powerware.comIf a power failure outlasts the backup time, the UPS shuts down in orderto prevent a total d

Strany 64

5Powerware®9150 User’s Guide www.powerware.comCHAPTER 2SAFETY WARNINGSThe only user operations permitted are:Starting up and shutting down the UPSOper