Powerware®9150User’s Guide8kVA-12.5kVAwww.powerware.com02/20/2001
Safety Warnings6Powerware®9150 User’s Guide www.powerware.comDANGERThisUPScontainsLETHAL VOLTAGES.Allrepairsand serviceshould be performedbyAUTHORIZED
Safety Warnings7Powerware®9150 User’s Guide www.powerware.comSikkerhedsanvisningerFAREDenneUPS(ubrudt strømforsyning)indeholderLIVSFARLIG SPÆNDING.Alr
Safety Warnings8Powerware®9150 User’s Guide www.powerware.comBelangrijke VeiligheidsinstructiesGEVAARDezeUPSbevat LEVENSGEVAARLIJKEELEKTRISCHE SPANNIN
Safety Warnings9Powerware®9150 User’s Guide www.powerware.comTärkeitä turvaohjeitaVAARATämä UPS sisältää HENGENVAARALLISIA JÄNNITTEITÄ. Kaikkikorjauks
Safety Warnings10Powerware®9150 User’s Guide www.powerware.comConsignes de SécuritéConsignes Importantes De Sécurité - Conserver Ces InstructionsCette
Safety Warnings11Powerware®9150 User’s Guide www.powerware.comWichtige SicherheitsanweisungenWARNUNGLebensgefahr! DieseUSVenthält TÖDLICHE SPANNUNGEN!
Safety Warnings12Powerware®9150 User’s Guide www.powerware.comImportanti istruzioni di sicurezzaPERICOLOLaTENSIONE contenuta inquestogruppo staticodi
Safety Warnings13Powerware®9150 User’s Guide www.powerware.comViktig SikkerhetsinformasionFARLIGDenneUPS’en inneholder LIVSFARLIGE SPENNINGER.Allrepar
Safety Warnings14Powerware®9150 User’s Guide www.powerware.comRegulamentos de SegurançaCUIDADOOUPScontémVOLTAGEMMORTAL. Todos osreparose assistênciaté
Safety Warnings15Powerware®9150 User’s Guide www.powerware.comRequisitos de seguridadPELIGROEsteUPS(suministrodealimentaciónpermanente)contieneVOLTAJE
FCC StatementThe Powerware 9150 UPS configurations vary. Some configurations may or may not be classified by the FederalCommunications Commission (FCC
Safety Warnings16Powerware®9150 User’s Guide www.powerware.comViktig säkerhetsinformationFARADennaUPS-enhetinnehåller LIVSFARLIGSPÄNNING.ENDAST AUKTOR
17Powerware®9150 User’s Guide www.powerware.comCHAPTER 3INSTALLATIONThe following section describes UPS storage requirements, UPS setup,and the instal
Installation18Powerware®9150 User’s Guide www.powerware.comUPS SetupWhen the UPS is in use, allow a minimum of 4 inches (100 mm) forventilation on bot
Installation19Powerware®9150 User’s Guide www.powerware.comSeismic MountingThe Powerware 9150 has a seismic mounting option. The UPS isshipped withflo
Installation20Powerware®9150 User’s Guide www.powerware.comSelecting an Installation OptionIn addition to the standard Powerware 9150, the UPS has an
Installation21Powerware®9150 User’s Guide www.powerware.comUse the following procedure to connect utility power and load to theUPS:1. Verify that the
Installation22Powerware®9150 User’s Guide www.powerware.comLeft Panel ScrewsFigure 5. Removing the UPS Panels
Installation23Powerware®9150 User’s Guide www.powerware.com6. Verify that the UPS battery breaker CB1 and optional CB2 are inthe OFF position (see Fig
Installation24Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Hardwired TerminationsWireFunction TerminalPosition*Upstream CircuitBreakerS
Installation25Powerware®9150 User’s Guide www.powerware.com9. Reinstall the UPS left side panel. (Do not reinstall the frontpanel at this time.)10. Lo
Table of ContentsiPowerware®9150 User’s Guide www.powerware.comTABLE OF CONTENTS1 Introduction 1...UP
Installation26Powerware®9150 User’s Guide www.powerware.comLeft Panel ScrewsFigure 8. Removing the UPS Panels
Installation27Powerware®9150 User’s Guide www.powerware.com4. Verify that the UPS battery breaker CB1 and optional CB2 are inthe OFF position (see Fig
Installation28Powerware®9150 User’s Guide www.powerware.comScrews fromUPS panel; 3 oneach sidereused for PDMWireCover forOutput ConduitLandingFigure 1
Installation29Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Hardwired Terminations for Optional PDMWireFunctionTerminal UpstreamSuggeste
Installation30Powerware®9150 User’s Guide www.powerware.com10. Connect the wire cover to the PDMusing the two screwsprovided (see Figure 10).11. Reins
Installation31Powerware®9150 User’s Guide www.powerware.comCB2CB1 SafetyWireFigure 12. EBC Front Panel5. Verify that the circuit breakers CB1 and CB2
Installation32Powerware®9150 User’s Guide www.powerware.comBattery CableCoverPlateBattery ConnectorUPSEBCEBCEBC Cover Plate (foradditional EBCs)Batter
Installation33Powerware®9150 User’s Guide www.powerware.com10. Lower the leveling feet to prevent the EBC from rolling (doesnot apply for seismic moun
Installation34Powerware®9150 User’s Guide www.powerware.comIf the UPS does not start and an LED other than the UPS ONindicator is blinking, the UPS is
Installation35Powerware®9150 User’s Guide www.powerware.comUPS Startup on BatteryNOTE Beforeusingthisfeature, theUPSmusthave beenpowered byutility pow
Table of ContentsiiPowerware®9150 User’s Guide www.powerware.com4 Operation 39...ControlPanelFuncti
Installation36Powerware®9150 User’s Guide www.powerware.comConfiguring Voltage and FrequencyThe UPS automatically attempts to match the voltage and fr
Installation37Powerware®9150 User’s Guide www.powerware.comManual Configuration ModeTo change the nominal output voltage and frequency from the frontp
Installation38Powerware®9150 User’s Guide www.powerware.com
39Powerware®9150 User’s Guide www.powerware.comCHAPTER 4OPERATIONThis chapter contains information on how to use the Powerware 9150,including UPS shut
Operation40Powerware®9150 User’s Guide www.powerware.comFigure 15. LED PanelThe following table shows the LED status and description.LED Status Descri
Operation41Powerware®9150 User’s Guide www.powerware.comDescriptionStatusLEDOVERTEMP OnorBlinkingOne of the main UPS components is too hot or the fan
Operation42Powerware®9150 User’s Guide www.powerware.comThe Powerware 9150 can operate in Normal, Bypass, or Battery Mode.The UPS automatically switch
Operation43Powerware®9150 User’s Guide www.powerware.comUPS ShutdownTo shut down the UPS:1. Remove the front panel. Lift from the bottom of the panel
Operation44Powerware®9150 User’s Guide www.powerware.comMaintenanceBypass SwitchONOFFF1BatteryNeutralFuseCB1InternalBatteryCB2(Optional)ExternalBatter
Operation45Powerware®9150 User’s Guide www.powerware.comWARNINGIfthe inputfrequencyisnot correctand the UPS is notsynchronizedto utilitypower(LINEONin
1Powerware®9150 User’s Guide www.powerware.comCHAPTER 1INTRODUCTIONThe Powerware 9150 is a double-conversion, online uninterruptiblepower supply (UPS)
Operation46Powerware®9150 User’s Guide www.powerware.comComputer and Alarm ConnectionsAn interface for direct communication with your computer system
Operation47Powerware®9150 User’s Guide www.powerware.comConnectUPSMounting BracketCommunicationCablesFigure 19. Hardware ConnectionsRS-232 Serial Data
Operation48Powerware®9150 User’s Guide www.powerware.com123478659Male Connector(LanSafe III/FailSafe III or Modem)543287916Female Connector(OnliNet or
Operation49Powerware®9150 User’s Guide www.powerware.comIsolated Alarm Relay InterfaceThe isolated alarm relay interface uses a 15-pin, male, 42D-subc
Operation50Powerware®9150 User’s Guide www.powerware.comRemote Emergency Power-off InputREPO is used to shut down the UPS from a distance. This featur
51Powerware®9150 User’s Guide www.powerware.comCHAPTER 5SPECIFICATIONSPowerware 9150 Technical SpecificationsRatedPower 8 kVA, 10 kVA, 12.5 kVA at 0.7
Specifications52Powerware®9150 User’s Guide www.powerware.comPowerware 9150 Model SpecificationsModel12.5kVAInputCurrent 54A 56A 52A 52A 49AOutputVolt
Specifications53Powerware®9150 User’s Guide www.powerware.comModel8 kVAInputCurrent 39A 40A 36A 36A 35AOutputVoltage 100/200V 110/220V 120/240V 120/20
Specifications54Powerware®9150 User’s Guide www.powerware.comEnvironmental and Safety SpecificationsAmbientTemperature 0 Cto+40C operating+15C to +25
55Powerware®9150 User’s Guide www.powerware.comCHAPTER 6TROUBLESHOOTINGThe Powerware 9150 is designed for durable, automatic operationandalso alerts y
Introduction2Powerware®9150 User’s Guide www.powerware.comUPS Model and Battery ConfigurationsThere are two important considerations whenselecting the
Troubleshooting56Powerware®9150 User’s Guide www.powerware.comActionPossibleCauseIndicatororAlarmALARMOn or Blinking1 short and 4 long beeps indicate
Troubleshooting57Powerware®9150 User’s Guide www.powerware.comService and SupportIf you have any questions or problems with your UPS, call for service
Troubleshooting58Powerware®9150 User’s Guide www.powerware.com
Powerware 9150 Limited Warranty (US Only)This limited warranty applies only to units installed in the fifty United States of America. PowerwareCorpora
60Powerware®9150 User’s Guide www.powerware.com60
Introduction3Powerware®9150 User’s Guide www.powerware.comIf the total load requirements of the equipment exceeds the capacity ofthe UPS, you must eit
Introduction4Powerware®9150 User’s Guide www.powerware.comIf a power failure outlasts the backup time, the UPS shuts down in orderto prevent a total d
5Powerware®9150 User’s Guide www.powerware.comCHAPTER 2SAFETY WARNINGSThe only user operations permitted are:Starting up and shutting down the UPSOper